Installation Precautions

The reducer must be installed on a flat and solid base, and the foot bolts must be tightened and shockproof.

The connecting shafts of the prime mover-reducer-working machine must be accurately aligned with each other after installation.

The outer diameter tolerance of the shaft extensions at the input and output ends of the reducer are made according to h6, and the inner holes of the matching couplings, pulleys, sprockets and other transmission parts must be prepared according to the appropriate tolerance size to avoid over-tightening and damage to the bearings, and over-loosening and affecting the normal power transmission.

When the transmission parts such as sprockets and gears are installed on the shaft extension, they should be as close to the bearing as possible to reduce the bending stress of the shaft extension.

When ordering and using various types of WPD reducers, if the weight of the motor is too large, a support device should be provided.

 

Precautions for use

Before use, check whether the reducer type structure, center distance specification, transmission ratio, input shaft connection method, output shaft structure, input shaft output shaft direction and rotation direction meet the use requirements.

Inject the appropriate brand of lubricant according to the requirements specified in the “Selection and Use of Lubricants” on the sample. After refueling, tighten the breather on the top and pull out the small cone plug on the breather before the reducer can start running. It is necessary to select the appropriate brand of lubricant, control the appropriate amount of refueling, and change the oil in time according to the specified requirements. In particular, pay attention to the replacement of new oil after 100 hours of first use.

If an abnormal situation occurs during use, the machine should be stopped and checked in time, and consult the supplier.

 

Selection and use of lubricating oil

Before using the worm reducer, inject N220~N320 (ambient temperature -30℃~40℃) or N320~N460 (ambient temperature 40℃~65℃) lubricating oil to the center of the oil mark, and remove the small cone plug on the breather. After the first 100 hours of use, clean the inside and replace with new oil, and change the oil every 2500 hours thereafter.

When using the reducer, you can choose the lubricating oil according to the table below.

lubrication oil instructions for WP series worm-gearbox